New Products | Our Location | Contact Us | Site Map  
Measurement & Control Technology Ltd Measurement & Control Technology Ltd 
  Tel: +44(0)1902 342405  Fax: +44(0)1902 461920 Email: sales@mct-ltd.co.uk  

Signal Converters

Wireless Data Acquisition
Wireless Data Acquisition
New Products
New Products

  We accept Mastercard We accept VISA We accept Switch  
  Get Adobe Reader  

Signal Converters

[641]  [6570]  [6580]  [6821]  [6841]  [6720]  [6740]  [6770]  [6420]  [7100]  [RMD 680]  [PXL 10]

641 DIN rail signal converter

  • Current inputs 0/4..20 mA
  • Voltage inputs 0..5, 0..10 V, +/-10V
  • Potentiometer
  • Outputs 0/4..20 mA, 0..5/10V, +/-10V, or passive 2-wire 4-20 mA
  • Power supply for 2 wire transmitter
  • Galvanic isolation
  • Four selectable dampings
  • Nominal accuracy 0.05% of range
  • Power supply 24 VDC +/-10%
  • mV inputs on request
Signal Converters - 641 DIN rail signal converter See also;
[641]
[6570]
[6580]
[6821]
[6841]
[6720]
[6740]
[6770]
[6420]
[7100]
[RMD 680]
[PXL 10]
back to top^

Data Sheets

641 DIN rail signal converter (115kb) Portable Data Format Document




6570 DIN rail signal isolator

  • Input 4..20 mA
  • Output alternatives 0..20 mA, 4..20 mA or 0-10V
  • Galvanic isolation 3000V
  • Auxiliary power supply not required
  • Accuracy 0.05% of span
Signal Converters - 6570 DIN rail signal isolator See also;
[641]
[6570]
[6580]
[6821]
[6841]
[6720]
[6740]
[6770]
[6420]
[7100]
[RMD 680]
[PXL 10]
back to top^

Data Sheets

6570 DIN rail signal isolator (151kb) Portable Data Format Document




6580 DIN rail signal isolator

  • Very slim, only 9.5mm
  • 2-wire output 4..20 mA
  • Inputs 0..20 mA, 4..20 mA or 0-10V
  • Galvanic isolation 1000V
  • Power supply 10..34 VDC
  • Voltage drop in input loop 1V
  • Output load 700 ohm (with 24VDC)
  • Accuracy 0.05% of span
Signal Converters - 6580 DIN rail signal isolator See also;
[641]
[6570]
[6580]
[6821]
[6841]
[6720]
[6740]
[6770]
[6420]
[7100]
[RMD 680]
[PXL 10]
back to top^

Data Sheets

6580 DIN rail signal isolator (102kb) Portable Data Format Document




6821 Programmable Dual-channel transmitter

  • 2 universal independently programmable inputs
  • 2 programmable analogue outputs
  • 2 alarm relays
  • Mathematical & conditional operations
  • Modbus RTU & RS485 serial communications
  • Power supply 90-240 VAC or 24VDC
Signal Converters - 6821 Programmable Dual-channel transmitter See also;
[641]
[6570]
[6580]
[6821]
[6841]
[6720]
[6740]
[6770]
[6420]
[7100]
[RMD 680]
[PXL 10]
back to top^

Data Sheets

6821 Programmable Dual-channel transmitter (305kb) Portable Data Format Document




6841 Strain gauge programmable DIN rail transmitter

  • Strain guage sensors with 4 or 6 wire connection
  • Excitation to sensors 10 V, max 150 mA
  • Red LED display on front panel
  • Configuration via front panel keys or programme software
  • 0/4..20 mA or 0-10 V output
  • RS 485 serial communications
  • 2 alarm relays
  • Taring via front panel keys or digital input
  • Measuring accuracy < 0.05%
  • Power supply 12..32 VDC or 85..240 VAC
  • 6 points linearisation
Signal Converters - 6841 Strain gauge programmable DIN rail transmitter See also;
[641]
[6570]
[6580]
[6821]
[6841]
[6720]
[6740]
[6770]
[6420]
[7100]
[RMD 680]
[PXL 10]
back to top^

Data Sheets

6841 Strain gauge programmable DIN rail transmitter (222kb) Portable Data Format Document




6720 Loop powered programmable DIN rail transmitter

  • Process input 0/4..20 mA, 0..5/10V or -20..+20 mA
  • Potentiometer
  • -100..+100 mV
  • Thermocouples B,C, D, E, G, J, K, L, N, R, S, T
  • RTD`s Pt100, Pt500, Pt1000, ja Ni100, Ni1000
  • Outputs 4..20 mA
  • Programming via programme software or hand held programmer
  • Galvanic isolation between input, output & power supply
  • Compact size
  • Power supply 24 VDC
Signal Converters - 6720 Loop powered programmable DIN rail transmitter See also;
[641]
[6570]
[6580]
[6821]
[6841]
[6720]
[6740]
[6770]
[6420]
[7100]
[RMD 680]
[PXL 10]
back to top^

Data Sheets

6720 Loop powered programmable DIN rail transmitter (137kb) Portable Data Format Document




6740 Programmable DIN rail transmitter

  • Process input 0/4..20 mA, 0..5/10V or -20..+20 mA
  • Potentiometer
  • -100..+100 mV
  • Thermocouples B,C, D, E, G, J, K, L, N, R, S, T
  • RTD`s Pt100, Pt500, Pt1000, ja Ni100, Ni1000
  • Outputs 0..20, 4..20 mA, 0..5, 0..10V
  • Programming via programme software or hand held programmer
  • Galvanic isolation between input, output & power supply
  • Compact size
  • Power supply 24 VDC
Signal Converters - 6740 Programmable DIN rail transmitter See also;
[641]
[6570]
[6580]
[6821]
[6841]
[6720]
[6740]
[6770]
[6420]
[7100]
[RMD 680]
[PXL 10]
back to top^

Data Sheets

6740 Programmable DIN rail transmitter (71kb) Portable Data Format Document




6770 DIN rail difference transmitter

  • Inputs 0..20 mA, 4..20 mA
  • Output 0..20, 4..20 mA, 0..5, 0..10 V
  • (A+B) (A-B) (A+B)/2
  • Configuration via programme software or hand held programmer
  • Power supply 24 VDC
Signal Converters - 6770 DIN rail difference transmitter See also;
[641]
[6570]
[6580]
[6821]
[6841]
[6720]
[6740]
[6770]
[6420]
[7100]
[RMD 680]
[PXL 10]
back to top^

Data Sheets

Please contact M.C.T. for details




6420 DIN rail frequency to analogue transmitter with alarm

  • Input 0-20 Khz
  • Output 0(4)..20 mA or 0-10 V
  • Pulse output for divider or alarm
  • Power supply 24 VDC
Signal Converters - 6420 DIN rail frequency to analogue transmitter with alarm See also;
[641]
[6570]
[6580]
[6821]
[6841]
[6720]
[6740]
[6770]
[6420]
[7100]
[RMD 680]
[PXL 10]
back to top^

Data Sheets

6420 DIN rail frequency to analogue transmitter with alarm (202kb) Portable Data Format Document




7100 programmable DIN rail transmitter with RS485 Output

  • Process input 0/4..20 mA, 0..5/10V or -20..+20 mA
  • Potentiometer
  • -100..+100 mV
  • Thermocouples B, C, D, E, G, J, K, L, N, R, S, T
  • RTD`s Pt100, Pt500, Pt1000, ja Ni100, Ni1000
  • Output RS485 serial communications
  • Configuration via programme software or hand held programmer
  • Power supply 24 VDC
Signal Converters - 7100 programmable DIN rail transmitter with RS485 Output See also;
[641]
[6570]
[6580]
[6821]
[6841]
[6720]
[6740]
[6770]
[6420]
[7100]
[RMD 680]
[PXL 10]
back to top^

Data Sheets

7100 programmable DIN rail transmitter with RS485 Output (166kb) Portable Data Format Document




RMD 680 16 channel universal input transmitter

  • 16 individually configurable input channels
  • Process input 0/4..20 mA, 0..5/10V
  • Potentiometer & RTD
  • 0- 100 mV
  • Thermocouples B,C, D, E, G, J, K, L, N, R, S, T
  • Analogue output 0/4..20 mA or 0..10 V, channel selection via digital inputs or Min/Max value
  • 2 alarm relays
  • Digital front panel display
  • Modbus RTU & RS485 SCL protocols
  • Power supply 24 VDC, galvanically isolated from inputs
Signal Converters - RMD 680 16 channel universal input transmitter See also;
[641]
[6570]
[6580]
[6821]
[6841]
[6720]
[6740]
[6770]
[6420]
[7100]
[RMD 680]
[PXL 10]
back to top^

Data Sheets

RMD 680 16 channel universal input transmitter (155kb) Portable Data Format Document




PXL 10 Trip amplifier

  • Process input 0/4..20 mA, 0..5/10 or -10..+10V
  • Relay Output
  • Supply 230 VAC or 24 VDC
Signal Converters - PXL 10 Trip amplifier See also;
[641]
[6570]
[6580]
[6821]
[6841]
[6720]
[6740]
[6770]
[6420]
[7100]
[RMD 680]
[PXL 10]
back to top^

Data Sheets

PXL 10 Trip amplifier (63kb) Portable Data Format Document



New Products | Our Location | Contact Us | Site Map